ISSN: 0973-7510

E-ISSN: 2581-690X

Open Access
Shameema Mol N, Vishnu Prasad Shenoy , Seema Shetty and Kiran Chawla
Department of Microbiology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India.
J Pure Appl Microbiol. 2018;12(3):1405-1409
https://doi.org/10.22207/JPAM.12.3.43 | © The Author(s). 2018
Received: 20/06/2018 | Accepted: 12/08/2018 | Published: 30/09/2018
Abstract

Tuberculosis is a global emergency needing an early and accurate diagnosis for management and control. Smear microscopy is a rapid diagnostic method for detecting acid fast bacilli (AFB) and improvising this method would contribute in better detection rates. The present study compares the efficacy of various counter stains used in Auramine O staining method in examining sputum smears under fluorescence microscope. This was a prospective study conducted in the Department of Microbiology from January to March, 2017. 102 sputum specimens were collected during this period from patients clinically suspected with pulmonary tuberculosis. Five smears were prepared from each specimen, where each smear was stained with Auramine O staining technique using five different counter stains, 0.1% potassium permanganate, 0.1% methylene blue, 0.1% toluidine blue, 0.1% malachite green and undiluted blue ink. Among the 102 sputum specimens, 50(49.01%), 50(49.01%), 49(48.03%), 44(43.13%) and 48(47.05%) smears showed positive results using potassium permanganate, methylene blue, toluidine blue, malachite green and blue ink respectively. On comparing the degree of fluorescence exhibited by debris in these smears, using potassium permanganate, methylene blue, toluidine blue, malachite green and blue ink, fluorescence was observed in 22(21.6%), 11(10.8%), 46(45.1%), 0(0%) and 31(30.4%) smears respectively. When the counter stains were analyzed, there was a statistically significant difference for debris getting fluoresced (p<0.001).  In conclusion, methylene blue as a counter stain has almost equivalent effect compared to routinely used potassium permanganate. It has shown to have the best sensitivity and specificity, reduced debris fluorescence and better contrast in appreciating AFB.

Keywords

Tuberculosis, Acid Fast Bacilli, Light-Emitting Diode, Fluorescence Microscope, Counter stain

Article Metrics

Article View: 1424

Share This Article

© The Author(s) 2018. Open Access. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License which permits unrestricted use, sharing, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.